Brief introduction
Ms100 spo2 simulator is a kind of separated spo2 simulator, small and lightweight. It can carry out a series of tests for the oximeter by means of simulation means and gives knowledge of the veracity of the oximeter.
Since the oximeter manufacturer can use different R-curves, some R-curves used abroad have currently been embedded.
◆
Disconnected connection between simulator probe and host, operation and test are more convenient.
◆ 262k color and 320*240 tft, adjustable brightness.
◆ Press film button, makes the operation more convenient.
◆ Power supply with rechargeable lithium battery, can display the charging information of the battery.
◆ Key volume, can open or close.
Main functions
◆ Oxygen saturation simulation;
◆ Pulse rate simulation;
◆ Patient condition simulation before set;
◆ Can test the response time of the device;
◆ Can simulate the spo2 and pulse rate under different amplitudes;
◆ Can test the performance of the device under different interference source;
◆ Can select different r-curve.
Main parameters
◆ Spo2
measuring range: 35%~100% Resolution: 1% Error: If spo2 is 75%~100%, the error is greater between ± 2%
and ± p (p denotes the precision of the tested oximeter); if spo2 is 74%~50%, the error is greater between ± 2% and ± p; no definition if spo2 is less than 50%.
◆ Pulse rate
measuring range: 25bpm ~ 250bpm Resolution: 5bpm error: 1% ± 1bpm
◆ Amplitude
measuring range: 0.000%~20,000% resolution: 1% for 1,000%~20,000%
; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
◆ Patient condition
24 conditions pre-set and 8 conditions as standard after startup. The number of conditions can be adjusted by motion plane setup.
◆ Voltage
DC 3.6V~4.2V. ◆ Power supply
voltage 3.7 Rechargeable lithium battery × 1
◆ Battery
life charge and discharge not less than 500 times.
Accessories
◆ One MS100 User Manual
◆ One 5.0V Adapter